Σάββατο 7 Σεπτεμβρίου 2013

New dental MRI study yields best images yet

Dental researchers are making progress in their quest to develop a  practical magnetic resonance imaging (MRI) device that can be used in the operatory for  hard- and soft-tissue analysis and diagnosis.
For the first time ever—and only from Sirona—there's now a complete range of both digital  impressioning systems and single-visit chairside restoration systems to choose from, each  available in a wide range of configurations and price points to fit the framework of any practice and any budget.



SWIFT, a novel MRI technique, can simultaneously image both hard and soft dental tissue. Image courtesy of Djaudat Idiyatullin, Curt Corum, and Steen Moeller (CMRR).


In a technical paper published in Magnetic Resonance in Medicine (July 30, 2013 http://www.cmrr.umn.edu/news/20130823-dental-imaging/Idiyatullin13_mrm24893.pdf ),  scientists from the University of Minnesota Center for Magnetic Resonance Research outline  their efforts to optimize the MR signal from the teeth and supporting structures -- an  important step in improving overall image resolution, particularly with hard tissue.
"Dental MRI has the potential to be even more informative than x-ray imaging techniques by  visualizing, noninvasively and simultaneously, both hard and soft tissues in all three  spatial dimensions," they wrote. "However, clinical MRI has yet to attain the resolution of  cone-beam computerized tomography imaging."
At present, at least four MRI methods can be used to obtain images of densely calcified  dental tissues, the researchers noted: ultrashort echo times (TE), sweep imaging with  Fourier transformation (SWIFT), zero TE, and combined pointwise encoding time reduction with radial acquisition (PETRA).


These images show that by placing the MRI loop in the occlusal plane, the teeth and jaw bones are well positioned within the sensitive volume of the coil. All images courtesy of Djaudat Idiyatullin, University of Minnesota.

"These methods now make it feasible to image these tissues, but further RF [radio  frequency] coil refinement is still needed to optimize the MR signal from the teeth and supporting structures," they wrote.
The core of the issue involves overcoming patient motion, including swallowing. This  requirement that can only be met "when the coil positioning does not create excessive  discomfort for the patient," they explained.
Noting that the most comfortable coil position -- the occlusal plane -- has not been   seriously considered in previous dental MRI studies, the researchers set out to demonstrate  the advantages of using a loop coil in the occlusal position for dental imaging.
"In the occlusal position ... the sensitive volume of the coil encompasses the most important dental structures -- the teeth and their supporting structures -­while uninteresting tissues containing much higher proton density (cheeks, lips, and tongue) are outside the sensitive volume," they wrote.

For their experiments, they constructed a single loop using 10-mm-wide copper foil; the shape and size were chosen to  fit the average adult maxillary arch (about a 25-mm radius).  They covered the foil with sticky foam for comfort.  All phantom and in vivo images were acquired using a 4-tesla MRI system equipped with a Varian DirectDrive console. The in vivo images were obtained from a normal adult volunteer.
The coil was inserted in the occlusal position and isolated from intraoral structures and  saliva. The patient was placed in a supine position with his head in a holder specifically designed to restrict head motion. The researchers chose the SWIFT method for all imaging.

The resulting images are the first MRI panoramic images to demonstrate high nominal  resolution (0.3 mm3), the researchers noted. The images show that the teeth and jaw bones are well positioned within the sensitive volume of the coil, while the signal from the cheek and tongue yield low intensity, they added.
"The presented images and simulated data show the advantages of using a coil in the orthogonal orientation for dental applications," they wrote. "The transverse components of the B1 field of a surface coil can effectively be used for imaging of teeth and associated structures."


These are the first panoramic MR images to demonstrate high nominal resolution.



MR/PET: current status in clinical routine and market

Description of technology Positron Emission Tomography combined with Magnetic Resonance Imaging (PET-MRI) is an emerging technology rec...